EN
AR
Affiniti CVx Cardiology ultrasound system built for your everyday needs.

Affiniti CVx

Cardiology ultrasound system built for your everyday needs.

Find similar products

The Philips Affiniti CVx ultrasound system is a dedicated cardiovascular solution designed to meet the everyday demands of cardiology – helping you deliver better care to more patients.

Features
3D Auto LAA for left atrial appendage (LAA) sizing
3D Auto LAA for left atrial appendage (LAA) sizing

3D Auto LAA for left atrial appendage (LAA) sizing

Acquire the LAA ostium size quickly and easily. Automation reduces inter- or intra-user variability, increasing confidence during procedures.
X5-1 xMATRIX transducer
X5-1 xMATRIX transducer

X5-1 xMATRIX transducer

Our most leading-edge, versatile ultrasound transducer technology provides remarkable image quality and support for multiple interrogation capabilities and views not possible with 2D imaging. Designed to simplify your imaging workflow for even difficult-to-image patients.
AutoStrain LV, LA and RV aids in early detection of heart function change
AutoStrain LV, LA and RV aids in early detection of heart function change

AutoStrain LV, LA and RV aids in early detection of heart function change

Fast and reproducible longitudinal strain measurements for LV, LA and RV developed by TOMTEC using advanced automation technologies
Elevated vascular assessment
Elevated vascular assessment

Elevated vascular assessment

The lightweight L12-3 ERGO transducer provides superb detail and resolution, including MicroFlow Imaging for remarkable sensitivity in assessing blood flow. The eL18-4 transducer provides thin-slice imaging for exceptional tissue uniformity from near to far depth of field across a wide range of applications and depth requirements.
Collaboration Live for tele-ultrasound
Collaboration Live for tele-ultrasound

Collaboration Live for tele-ultrasound

Collaboration Live lets you extend your team without expanding it, because physical distance is no longer an obstacle. Securely access on-demand expertise for real-time guidance, decision support and standardization of patient care. 
3D Auto MV for mitral valve quantification
3D Auto MV for mitral valve quantification

3D Auto MV for mitral valve quantification

Analyze the complex anatomy of the mitral valve in 3D as well as its dynamic mechanics. This is useful from the initial discovery of mitral valve disease or pathology, to support device planning, and through monitoring of pre- and postoperative cases.
Customizable cardiology-focused interface
Customizable cardiology-focused interface

Customizable cardiology-focused interface

Designed to optimize cardiac workflow, the new interface delivers “walk-up usability” so that users can perform exams with minimal training. The interface can be configured to match your specific workflow, which means you can focus on the patient and images, rather than searching for controls.
Exceptional advances for pediatric imaging
Exceptional advances for pediatric imaging

Exceptional advances for pediatric imaging

From fetal echo to pediatrics to adult congenital patients, Affiniti CVx offers a depth of imaging capability combined with streamlined cardiac workflow to reduce the steps and time needed for challenging exams such as TTE and TEE.
Next-generation TEE imaging
Next-generation TEE imaging

Next-generation TEE imaging

The xMATRIX X8-2t transducer brings exceptional image quality and confidence to TEE imaging. Live 3D and Live 3D color flow, together with latest capabilities such as xPlane Doppler and MultiVue, help you to make a confident diagnosis in even the most complex cases.
iRotate to easily access an optimal view
iRotate to easily access an optimal view

iRotate to easily access an optimal view

Electronically access the optimum view within the acoustical window between ribs instead of manually rotating the transducer to search for an unobscured window. This can increase accuracy in measuring LV volumes because the image is less likely to be foreshortened.
  • 3D Auto LAA for left atrial appendage (LAA) sizing
  • X5-1 xMATRIX transducer
  • AutoStrain LV, LA and RV aids in early detection of heart function change
  • Elevated vascular assessment
See all features
3D Auto LAA for left atrial appendage (LAA) sizing
3D Auto LAA for left atrial appendage (LAA) sizing

3D Auto LAA for left atrial appendage (LAA) sizing

Acquire the LAA ostium size quickly and easily. Automation reduces inter- or intra-user variability, increasing confidence during procedures.
X5-1 xMATRIX transducer
X5-1 xMATRIX transducer

X5-1 xMATRIX transducer

Our most leading-edge, versatile ultrasound transducer technology provides remarkable image quality and support for multiple interrogation capabilities and views not possible with 2D imaging. Designed to simplify your imaging workflow for even difficult-to-image patients.
AutoStrain LV, LA and RV aids in early detection of heart function change
AutoStrain LV, LA and RV aids in early detection of heart function change

AutoStrain LV, LA and RV aids in early detection of heart function change

Fast and reproducible longitudinal strain measurements for LV, LA and RV developed by TOMTEC using advanced automation technologies
Elevated vascular assessment
Elevated vascular assessment

Elevated vascular assessment

The lightweight L12-3 ERGO transducer provides superb detail and resolution, including MicroFlow Imaging for remarkable sensitivity in assessing blood flow. The eL18-4 transducer provides thin-slice imaging for exceptional tissue uniformity from near to far depth of field across a wide range of applications and depth requirements.
Collaboration Live for tele-ultrasound
Collaboration Live for tele-ultrasound

Collaboration Live for tele-ultrasound

Collaboration Live lets you extend your team without expanding it, because physical distance is no longer an obstacle. Securely access on-demand expertise for real-time guidance, decision support and standardization of patient care. 
3D Auto MV for mitral valve quantification
3D Auto MV for mitral valve quantification

3D Auto MV for mitral valve quantification

Analyze the complex anatomy of the mitral valve in 3D as well as its dynamic mechanics. This is useful from the initial discovery of mitral valve disease or pathology, to support device planning, and through monitoring of pre- and postoperative cases.
Customizable cardiology-focused interface
Customizable cardiology-focused interface

Customizable cardiology-focused interface

Designed to optimize cardiac workflow, the new interface delivers “walk-up usability” so that users can perform exams with minimal training. The interface can be configured to match your specific workflow, which means you can focus on the patient and images, rather than searching for controls.
Exceptional advances for pediatric imaging
Exceptional advances for pediatric imaging

Exceptional advances for pediatric imaging

From fetal echo to pediatrics to adult congenital patients, Affiniti CVx offers a depth of imaging capability combined with streamlined cardiac workflow to reduce the steps and time needed for challenging exams such as TTE and TEE.
Next-generation TEE imaging
Next-generation TEE imaging

Next-generation TEE imaging

The xMATRIX X8-2t transducer brings exceptional image quality and confidence to TEE imaging. Live 3D and Live 3D color flow, together with latest capabilities such as xPlane Doppler and MultiVue, help you to make a confident diagnosis in even the most complex cases.
iRotate to easily access an optimal view
iRotate to easily access an optimal view

iRotate to easily access an optimal view

Electronically access the optimum view within the acoustical window between ribs instead of manually rotating the transducer to search for an unobscured window. This can increase accuracy in measuring LV volumes because the image is less likely to be foreshortened.

Specifications

System dimensions
System dimensions
Width
  • 57.2 cm
Height
  • 142.2-162.6 cm
Depth
  • 98.3 cm
Weight
  • 83.6 kg
Control panel
Control panel
Monitor size
  • 54.6 cm
Degrees of movement
  • 180 degrees
System dimensions
System dimensions
Width
  • 57.2 cm
Height
  • 142.2-162.6 cm
Control panel
Control panel
Monitor size
  • 54.6 cm
Degrees of movement
  • 180 degrees
See all specifications
System dimensions
System dimensions
Width
  • 57.2 cm
Height
  • 142.2-162.6 cm
Depth
  • 98.3 cm
Weight
  • 83.6 kg
Control panel
Control panel
Monitor size
  • 54.6 cm
Degrees of movement
  • 180 degrees
  • Affiniti CVx is available in selected countries. Please consult your Philips representative for further details.
  • *2020 IMV ServiceTrak™ Imaging Award winner for best ultrasound customer satisfaction, system performance and service.

Our site can best be viewed with the latest version of Microsoft Edge, Google Chrome or Firefox.